Stability analysis for masonry-arch structures and vaulted structures

Mirjana Bošnjak Klečina, Silva Lozančić

Abstract

The authors analyse cross vault of the Sts. Peter and Paul Church in Osijek, cross vault of the Đakovo Cathedral, and barrel vault of the Sts. Philip and Jacob church in Vukovar. The following actions are considered: permanent load, change in structural system, and increase in horizontal spacing between the supports. Two approaches are used. In the first approach, the analysis results in stress values. The second is used to determine the structural failure model for the maximum value of increase in horizontal spacing between supports, and for minimum horizontal acceleration of soil due to seismic action.

Keywords
cross vault, barrel vault, structural stability, permanent load, increase in horizontal spacing between supports, masonry structures

HOW TO CITE THIS ARTICLE:

Klečina, M. B., Lozančić, S.: Stability analysis for masonry-arch structures and vaulted structures, GRAĐEVINAR, 62 (2010) 5

OR:

Klečina, M. B., Lozančić, S. (2010). Stability analysis for masonry-arch structures and vaulted structures, GRAĐEVINAR, 62 (5)
Authors:

Mirjana Bošnjak Klečina
University of J. J. Strossmayer in Osijek,
Faculty of Civil Engineering

Silva Lozančić
University of J. J. Strossmayer in Osijek,
Faculty of Civil Engineering