Archive

UDK: 624.193:622.81
DOI: n/a

Published: Građevinar 56 (2004) 3
Paper type: Original scientific paper
Download article (Croatian): PDF
Download article (English): n/a

Calculating concentration of explosive fumes in the Stupe sewerage tunnel

Davor Bojanić

Abstract

Results obtained by mathematical modeling of the air flow and content of explosive fumes in the Stupe sewerage tunnel in Split, are presented. The modeling was performed in order to estimate exposure of this tunnel to the action of explosive and inflammable gases. Stationary flow calculation results, obtained during fan-assisted ventilation and during natural ventilation, are presented. It is emphasized that the modeling and analyses conducted in this research show that there is no gas hazard in this sewerage tunnel.

Keywords
natural ventilation, sewerage, explosive fumes, methane, hydrogen sulfide, artificial ventilation

HOW TO CITE THIS ARTICLE:

Bojanić, D.: Calculating concentration of explosive fumes in the Stupe sewerage tunnel, GRAĐEVINAR, 56 (2004) 3

OR:

Bojanić, D. (2004). Calculating concentration of explosive fumes in the Stupe sewerage tunnel, GRAĐEVINAR, 56 (3)
Authors:

Davor Bojanić
University of Split
Faculty of Civil Engineering, Architecture and Geodesy